Send Inquiry
stability chambers

stability chambers

Product Details:

X

Product Description

Temperature Range : 20°C to 60°C Accuracy : ± 0.2°C
Humidity Range : 40% RH to 95% RH Accuracy : ±2% RH
Temperature Uniformity : ±1°C Humidity Uniformity : ± 3% RH

  • Temperature & Humidity Suitable for 25 °C& 60% RH, 40 °C & 75% RH, 30 °C & 65% RH

  • Specially designed chambers to carry out stability studies at low humidity conditions such as 25°C & 40% RH, 40°C & 25% RH NMT, 30°C & 35% RH
Construction :


The unit is a double walled chamber, with glass wool / PUF insulation. Interior is made of Stainless Steeland Exterior is either made of Mild Steel finished in powder coating paint (powder coating on both sides of the mild steel) or Stainless Steel. The unit has full-length inner glass door and outside metal door with magnetic gasket and lock. The unit is provided with perforated Stainless Steel trays. Forcedair circulation for uniform temperature. PU wheels for easy move ability.

Intelligent Control System :


The controlling system having is PLC Base and PC communication on Ethernet

Heating System :


Long lasting stainless steel tubular heaters with s.s. fins.

Humidity System :


Humidity is by steam injection. A humidifier tank is fitted with two nos of heaters. One heater works as a stand by in case the regular heater fails. A water reservoir tank is connected to the boiler tank. Two boiler tanks are fitted with magnetic float switch and float valve. Magnetic float switch is provided for the safety of boiler as it facilitates in cutting off the heater supply in case of low level of water.
Sensor :


Rotronic make temperature and humidity transmitter 4-20mA used for measurement. Temperature in degree Celsius and Humidity in %RH with 0.1°C and 0.1%RH resolution.

Cooling System :


Hermitically sealed compressor coupled with evaporation coil and condenser, safe guarded by time delay circuit. CFC free refrigerant.

Alarms :


AuAudio and visual alarms are generated for temperature / humidity variation.

Safety :


ThThis unit is provided with safety devices for temperature and humidity over shoot in case of malfunction.


The unit works on 230 Volts AC and 50Hz mains supply.
 
SELECTION GUIDE :


Models

Capacity

Internal Dimension

External  Dimension

Weight (Kg)

Tray

Exterior M.S.

Exterior S.S.

Cuft.

Litres

HxWxD (mm)

HxWxD (mm)

Eqp

Shp

Nos

(mm)

NEC 208RT10I

NEC 208RT10SI

8

200

  600 x 600 x 600

1150 x 760 x 1045

200

275

2

560 x 560

NEC 212RT10I

NEC 212RT10SI

12

324

  900 x 600 x 600

1450 x 760 x 1045

250

325

3

560 x 560

NEC 216RT10I

NEC 216RT10SI

16

430

1200 x 600 x 600

1795 x 760 x 1095

275

350

4

560 x 560

NEC 221RT10I

NEC 221RT10SI

21

600

1200 x 700 x 700

1795 x 860 x 1195

300

400

4

660 x 660

NEC 228RT10I

NEC 228RT10SI

28

800

1200 x 800 x 800

1795 x 960 x 1295

325

425

4

760 x 760

NEC 234RT10I

NEC 234RT10SI

34

1000

1500 x 800 x 800

2095 x 960 x 1295

350

450

5

760 x 760


Eqp - Equipment
Shp
- Shipping
 
OPTIONALS :


  • Common Software: Chambers are connected on TCP/IP (Ethernet) with the centralized work station and transferring data in database. This centralized workstation provides the tool for viewing, trending and alarm management of chambers. It has date and time stamp audit trails and complies to US FDA 21 CFR Part 11.

  • Temperature and Humidity Scanner: 4 point scanner for temperature and humidity having 4 temperature and 4 humidity probes provided with alarms to monitor various parts of equipment.

  • Stand by Cooling System (Auto Switch Over): A fully functional cooling system can be provided as standby. It comes in operation automatically when the regular system fails to function.

  • Door Access System with Touch Screen Display: The door access system restricts access to the chamber to authorized persons only. In this system a physical lock is provided additional to this password access control is provided. Maximum six users can access the chamber.
  • Remote Alarm System: Alarm for Temperature & Humidity deviations. Indicator LED to identify equipment deviation. Alarm hooter test push button.

  • Mobile Alert System Suitable for Newtronic Equipments whenever the alarm is generated by the system the user has to acknowledge the alarm with in predetermined time. If the user fails to acknowledge the alarm will send as a sms to 6 predefined numbers.


V.V. ENGINEERS
GST :
House No-5-5-35/18/1&2, Plot No-73, Prasanthi Nagar, IE Kukatpally, Hyderabad - 500072, Telangana, India
Mr. V. Vijayanand (Proprietor)